Advance Valves have been satisfactorily tested to various stringent international and client specifications
quality-assurance-img
  • Fugitive Emission Testing as per ISO 15848
  • Cryogenic Tests as per BS 6364
  • Fire Safe Test as per API 6FA, ISO 10497
  • UV Cleaning for Oxygen Service
  • TAT (Type Approval Test) as per Shell Specifications
  • High Pressure Gas Tests
  • High Pressure Body Strength Test per UL 1091
  • Disc Strength Test as per EIL specifications
  • Seat and Seal Replaceability Test
  • Cyclic Cycle Testing for Proof of Design

Special points of interest

  • Radiographic Quality Castings
  • Valves Testing at half of the leakage specified in API 598
  • Quickly replaceable seat and seal arrangement
  • Quality System is based on the concept of 5S and Lean Manufacturing systems
  • Environment friendly products as per SIL 3 requirements
  • Pressure Parts Mill certification in line to EN 10204 3.1 as a minimum
  • Castings are visually accepted as per MSS SP 55 example A only
  • ISO 14001 compliant system
quality-assurance-img