We have in house Rockwell Hardness Tester, Poldi Hardness Tester, Shore A and Shore D hardness testers, Adhesion Testing machine for painting quality check. We outsource the tensile testing, impact testing, IGC testing as per ASTM A262 practice B and E, Ferrite Content, PREN evaluation, Chemical Wet Analysis, Spectro Analysis, Grain Size Determination and Micro structure testing are outsourced from our audited sub vendors.
testing_facility-img

Calibration

In House Calibration:- Pressure Gauges, Pressure Transducers, Torque Wrenches

Outsourced Calibration:- Dead Weight Tester, Vernier Calipers, Screw Gauges, Inside and Outside Micrometers, Depth Gauges, Thread Gauges, Ring and Plug Gauges, Surface Plates, Magnetic V Blocks, Tong Testers, Welding Machines, Flow Meters, Measuring Flasks, DFT gauges, WFT Gauges, Hygrometers, Thermometers

Testing facilities besides the standard hydro and pneumatic testing include
  • High pressure hydrostatic testing (upto 300 bar)
  • High pressure pneumatic testing (upto 200 bar)
  • Cryogenic Testing facility upto 48 inch valves
  • Water Quality Testing & Recycling System
  • Fugitive Emission Testing
  • Salt Contamination Test
  • Texture Profile Measurement
  • Fire Safe Testing
  • Oxygen Cleaning of Valves
  • High Pressure Helium testing (upto 167 bar / 2371 psi)
  • Helium Leak Detection with Hoods Method & Detector - Probe Method
  • Performance Testing with Actuators
  • Tensile Testing for vulcanized rubber
  • Valves various Prototype Testing
  • High Pressure & Temperature Testing
  • Blotter Testing
  • Spring Cycle Testing
equipment-img
Equipment

Advance Valves have in house Penetrant Testing set up, Magnetic Particle testing arrangement, UT thickness gauging, Positive Alloy Material Identification. These testing are essentially supported by calibrated equipment like Lux Meter, UV Light, Gauss Meter, Pie Gauges, Centrifuge Tubes, Reference Radiographs as per ASTM E446 and E186, Densitometers and Strips and Standard material reference blocks for PMI testing.

personnel-img
Personnel

Advance Valves have 1 nos. ASNT NDT level—III personnel, 20 nos. ASNT NDT level – II personnel, 12 nos. ASNT NDT level – I personnel in various NDT methods, across all the plants to provide the NDT coverage as per client’s requirements.

facilities-img
Facilities

We have in house Dark Room for radiographs interpretation, Canopies for Fluorescent PT and MT methods. X-ray, γ-Ray and Betatron machine and Ultrasonic Testing Machines, Leak Testing are outsourced from our udited sub vendors.